2000W PowerVerter Plus Industrial-Strength Inverter with 2 Outlets
| Product Name |
Eaton Tripp Lite series PowerVerter power inverter
|
| Catalog Number |
PV2000FC
|
| UPC |
037332042194
|
| Product Length/Depth |
19 in
|
| Product Height |
12.9 in
|
| Product Width |
14.7 in
|
| Product Weight |
39 lb
|
| Compliances |
RoHS
|
| Certifications |
UL Listed
|
| Global Catalog |
PV2000FC
|
| Product Type |
Power inverter
|
| Continuous Output Capacity (Watts) |
2000
|
| Cooling Method |
Fan
|
| Cord Length Details |
User supplies cabling; 2/0 gauge or larger recommended
|
| DC System Voltage (VDC) |
12
|
| Form Factor Supported |
Mounting slots enable permanent placement of inverter on any horizontal surface (see manual for additional mounting information)
|
| Front Panel LEDs |
Set of 6 LEDs offers continuous status information on load percentage (6 levels reported) and battery charge level (7 levels reported). See manual for sequences
|
| Input Connection Type |
Set of 2 DC bolt-down wiring terminals
|
| LED Indicators |
Set of 6 LEDs offers continuous status information on load percentage (6 levels reported) and battery charge level (7 levels reported). See manual for sequences
|
| Load Sensing |
Optional load sense function enables automatic inverter shutoff and startup as connected equipment is powered off and on. Front panel load sense potentiometer can be set to shutoff or turn on inverter power in response to loads of any level
|
| Amperage Rating per watt |
Full continuous load - 200A at 12V DC, No load - 2.2A at 12V DC
|
| Output Capacity (Watts) |
2000
|
| Output Frequency Regulation |
60 Hz (+/- 0.3 Hz)
|
| Output Voltage Regulation |
Maintains PWM sine wave output voltage of 120 V AC (+/-5%)
|
| Overload Protection |
Circuit breaker
|
| Peak Output Capacity (Watts) |
4000
|
| Power Cord Jacket Type |
SJT
|
| Frequency Compatability |
60 Hz
|
| Recommended Electrical Service |
Requires 12V DC input source capable of delivering 200A for the required duration (when used at full capacity). For automotive applications, professional hardwire installation with 400A battery system fusing is recommended
|
| Relative Humidity |
0-95% non-condensing
|
| Switches |
3-position on/off/remote switch enables simple on/off power control plus "remote" setting that enables distant on/off control of the inverter system when used in conjunction with optional APSRM4 accessory
|
| Voltage Compatibility (VDC) |
12
|
| Total outlets |
2
|
| Material |
Polycarbonate
|
| Output Receptacles |
5-15R
|
| Package Contents |
Instruction manual
PV2000FC Inverter |
| Product Features |
Set of 2 DC bolt-down wiring terminals
|
| Nominal Output Voltage |
120V
|
Support from Eaton